13. Durability

13.1. Electrical Noise

No malfunction occurred when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp) was
added to a power supply line.

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

PCS: 0.9

Resolution: 0.25

mm

Symbology: 9-digit

Code-39

Quiet Zone:

10 mm

N/W Ratio:

1:2.5

Distance: 90

mm

Angle:

α = 0° β = 15° γ = 0°

Curvature: R

=

Power Supply Voltage: 5.0 V

13.2. Shock

13.2.1.

Drop Test (without packaging)

No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor three
times on each of 5 sides.

Figure 26: Drop test

13.2.2.

Drop Test (with individual packaging)

No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor on
each of one corner, three edges, and six sides (10 drop tests in total).