System components, Outback ac breakers, Outback dc breakers – Outback Power Systems Systems User Manual
Page 20: Outback pv ground fault protection system, Outback dc breaker specifi cations, Outback ac breaker specifi cations, Outback pv ground fault protection specifi cations
28
l
OutBack Power Systems Inc.
2005
System Components
OutBack AC Breakers
Hydraulic-Magnetic type breakers that are DIN
rail “snap-in” mountable and can be used for in-
put, output or load circuits. 1/2" (13 mm) wide.
OutBack DC Breakers
Panel mounted Hydralic-Magnetic type breakers
which can be used for DC sources, inverters or
load circuits. 3/4" (18 mm) wide.
OutBack PV Ground Fault
Protection System
Th e OBDC-GFP/2 is required by the NEC for
PV arrays mounted on residential dwelling
roofs. It can be used with the PS2DC, PS4DC or
PS1. An OBDC-GFP/2 protects wiring and sys-
tem components for one or two PV arrays: dual
80 amp PV circuits 150 VDC max VOC. Th e
OBDC-GFP/2 system includes the GFP unit, a
ground bus bar, neutral and ground connection
wiring and mounting hardware.
OutBack DC Breaker Specifi cations
Model
Current Rating
Stud Terminal Size
Width
OBDC-250
250 amp 125 VDC
3/8 “ stud
1.5" (39 mm)
OBDC-175
175 amp 125 VDC
3/8” stud
1.5" (39 mm)
OBDC-125
125 amp 125 VDC
5/16" stud
1.0” (26 mm)
OBDC-100
100 amp 125 VDC
5/16” stud
1.0” (26 mm)
OBDC-80
80 amp 150 VDC
5/16” stud
0.75" (19 mm)
OBDC-70
70 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-60
60 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-50
50 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-40
40 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-30
30 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-20
20 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-15
15 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-10
10 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-5
5 amp 150 VDC
1/4” stud
0.75" (19 mm)
OBDC-1
1 amp 150 VDC
1/4” stud
0.75" (19 mm)
18
OutBack AC Breaker Specifi cations
Model
Rating
Version
Width
OBAC-50 120VAC
Single Pole
0.5” (13 mm)
OBAC-50D 120/240VAC
Dual Pole
1.0” (26 mm)
OBAC-50-3P 120/208VAC
Three Pole
1.5” (39 mm)
OBAC-50DE 240VAC
Dual Pole
1.0” (26 mm)
OBAC-30 120VAC
Single Pole
0.5” (13 mm)
OBAC-30D 120/240VAC
Dual Pole
1.0” (26 mm)
OBAC-25D 120/240VAC
Dual Pole
1.0” (26 mm)
OBAC-20 120VAC
Single Pole
0.5” (13 mm)
OBAC-20D 120/240VAC
Dual Pole
1.0” (26 mm)
OBAC-15 120VAC
Single Pole
0.5” (13 mm)
OBAC-15D 120/240VAC
Dual Pole
1.0” (26 mm)
OutBack PV Ground Fault Protection Specifi cations
Model
Description
Stud Terminal Size
OBDC-GFP/2
80 amp at 150 VDC
2 Poles - Requires 3