System components, Outback ac breakers, Outback dc breakers – Outback Power Systems Systems User Manual

Page 20: Outback pv ground fault protection system, Outback dc breaker specifi cations, Outback ac breaker specifi cations, Outback pv ground fault protection specifi cations

background image

28

l

OutBack Power Systems Inc.

2005

System Components

OutBack AC Breakers

Hydraulic-Magnetic type breakers that are DIN

rail “snap-in” mountable and can be used for in-

put, output or load circuits. 1/2" (13 mm) wide.

OutBack DC Breakers

Panel mounted Hydralic-Magnetic type breakers

which can be used for DC sources, inverters or

load circuits. 3/4" (18 mm) wide.

OutBack PV Ground Fault
Protection System

Th e OBDC-GFP/2 is required by the NEC for

PV arrays mounted on residential dwelling

roofs. It can be used with the PS2DC, PS4DC or

PS1. An OBDC-GFP/2 protects wiring and sys-

tem components for one or two PV arrays: dual

80 amp PV circuits 150 VDC max VOC. Th e

OBDC-GFP/2 system includes the GFP unit, a

ground bus bar, neutral and ground connection

wiring and mounting hardware.

OutBack DC Breaker Specifi cations

Model

Current Rating

Stud Terminal Size

Width

OBDC-250

250 amp 125 VDC

3/8 “ stud

1.5" (39 mm)

OBDC-175

175 amp 125 VDC

3/8” stud

1.5" (39 mm)

OBDC-125

125 amp 125 VDC

5/16" stud

1.0” (26 mm)

OBDC-100

100 amp 125 VDC

5/16” stud

1.0” (26 mm)

OBDC-80

80 amp 150 VDC

5/16” stud

0.75" (19 mm)

OBDC-70

70 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-60

60 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-50

50 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-40

40 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-30

30 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-20

20 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-15

15 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-10

10 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-5

5 amp 150 VDC

1/4” stud

0.75" (19 mm)

OBDC-1

1 amp 150 VDC

1/4” stud

0.75" (19 mm)

18

OutBack AC Breaker Specifi cations

Model

Rating

Version

Width

OBAC-50 120VAC

Single Pole

0.5” (13 mm)

OBAC-50D 120/240VAC

Dual Pole

1.0” (26 mm)

OBAC-50-3P 120/208VAC

Three Pole

1.5” (39 mm)

OBAC-50DE 240VAC

Dual Pole

1.0” (26 mm)

OBAC-30 120VAC

Single Pole

0.5” (13 mm)

OBAC-30D 120/240VAC

Dual Pole

1.0” (26 mm)

OBAC-25D 120/240VAC

Dual Pole

1.0” (26 mm)

OBAC-20 120VAC

Single Pole

0.5” (13 mm)

OBAC-20D 120/240VAC

Dual Pole

1.0” (26 mm)

OBAC-15 120VAC

Single Pole

0.5” (13 mm)

OBAC-15D 120/240VAC

Dual Pole

1.0” (26 mm)

OutBack PV Ground Fault Protection Specifi cations

Model

Description

Stud Terminal Size

OBDC-GFP/2

80 amp at 150 VDC

2 Poles - Requires 3