Ps1 specifications – Outback Power Systems Systems User Manual
Page 15
2005
OutBack Power Systems Inc.
l
28
13
PS1 Specifications
Sealed Models
Vented Models
PS1-2500
PS1-3000
Continuous Power Rating
At 40° C
2500 VA
3000 VA
At 25° C
3000 VA
3600 VA
AC Voltage / Frequency Output
120 VAC 60 Hz
120 VAC 60 Hz
AC Input Current Maximum
AC Transfer Switch
50 amps AC
50 amps AC
Battery Charger
16 amps AC with automatic back-off
20 amps AC with automatic back-off
Maximum AC Surge Current
Peak (1 millisecond)
70 amps AC
70 amps AC
RMS (5 seconds)
50 amps AC
50 amps AC
Maximum PV Array Wattage
3300 watts DC stc rating
3300 watts DC stc rating
PV Open Circuit Voltage
Maximum
150 VDC
150 VDC
MPPT Input Voltage Range
44 to 135 VDC
44 to 135 VDC
PV Array Ground Fault Protection
Standard - 80 amp DC
Standard - 80 amp DC
Inverter Efficiency
Typical
91% (not CEC Certified)
91% (CEC Certified)
Peak
93%
93%
MPPT Efficiency
98%
98%
Overall System Efficiency
Typical
89%
89%
Peak
92%
92%
Battery Voltage - Nominal
48 VDC
48 VDC
Minimum / maximum operating range
40 to 60 VDC
40 to 60 VDC
Battery Charge Rate
Inverter
35 amps DC
45 amps DC
MX60
60 amps DC
60 amps DC
AC Output Voltage Regulation
Typical
5%
5%
Nominal
120 VAC
120 VAC
AC Output Current
Inverting
25.0 amps AC
30.0 amps AC
Selling
20.8 amps AC
25.0 amps AC
Total Harmonic Distortion
Inverting
2% VAC THD
2% VAC THD
Selling
< 5% current THD per UL1741 conditions
< 5% current THD per UL1741 conditions
AC Transfer Switch Speed
Typical
< 16 Milliseconds
< 16 Milliseconds
Battery Temperature Sensor
Included
Included
Operating Temperature Range
-40° C to 60° C (power derated above 25° C)
-40° C to 60° C (power derated above 25° C)
Recommended Minimum Energy Storage
4 kWHRS at 80% discharge
4 kWHRS at 80% discharge
Recommended Batteries
Four AGM type 31 or type 27 sealed VRLA
Four AGM type 31 or type 27 sealed VRLA
Communications
Optional MATE system display with RS232 port
Optional MATE system display with RS232 port
Enclosure Materials
Powder coated aluminum, stainless steel hardware
Powder coated aluminum, stainless steel hardware
Mounting
Wall mount, 16 on center studs
Wall mount, 16" on center studs
Recommended Mounting Hardware
5/16 x 2.5” Lag Bolts - three per side minimum
5/16 x 2.5” Lag Bolts - three per side minimum
System Enclosure Dimensions (H x W x D)
Unit
31.3 x 17.25 x 12.9” (80 x 44 x 33 cm)
31.3 x 17.25 x 12.9” (80 x 44 x 33 cm)
Shipping
40.5 x 20.5 x 17.25” (103 x 52 x 44 cm)
40.5 x 20.5 x 17.25” (103 x 52 x 44 cm)
Battery Enclosure Dimensions (H x W x D)
Unit
36.25 x 17.25 x 12.55” (92 x 44 x 32 cm)
36.25 x 17.25 x 12.55” (92 x 44 x 32 cm)
Shipping
43.25 x 20.25 x 16.75” (110 x 51 x 43 cm)
43.25 x 20.25 x 16.75” (110 x 51 x 43 cm)
System Weight
Unit
107 lbs (49 kg)
107 lbs (49 kg)
Shipping
117 lbs (53 kg)
117 lbs (53 kg)
Battery Enclosure Weight (without batteries)
Unit
29 lbs (13 kg)
29 lbs (13 kg)
Shipping
47 lbs (21 kg)
47 lbs (21 kg)
Certifications
ETL certified to the UL1741 standard
ETL certified to the UL1741 standard
Anti-Islanding Measures
UL1741 compliant
UL1741 compliant
Warranty
5 year limited repair warranty standard
5 year limited repair warranty standard
Field Installed Options
MATE or MATE2 remote system display
MATE or MATE2 remote system display
OBAC breakers for additional AC load circuits
OBAC breakers for additional AC load circuits
OBPV breakers for PV array series string protection
OBPV breakers for PV array series string protection