30

2 Basic Operation

Bidirectional Correction

* Only when the printing direction at the [PRINT QUALITY] menu has been set to [BI-DIRECTION] (bidirectional)

This adjusts slippage when performing bidirectional printing.
Make this adjustment when you have replaced the material with a different type or adjusted the head height.

Press the [MENU] key and [ ] key to make the
following screen appear on the display.

1

Press the [

] key to make the following screen

appear on the display.

2

Press the [ENTER] key to start printing a test pattern.

3

Check the test pattern and choose a value with no
displacement.

4

MENU
BIDIRECTION

BIDIRECTION
TEST PRINT

+15 +14 +13 +12 +11 +10 +9

+8

+7

+6

+5

+4

+3

+2

+1

0

-1

-2

-3

-4

-5

-6

-7

-8

-9

-10 -11 -12 -13 -14 -15

Test pattern

Value with no displacement

Current setting

Press the [ ] key to make the following screen
appear on the display.

5

Press the [

] key to make the following screen

appear on the display.

6

Use the [ ] and [ ] keys to set the value you
checked in step 4, then press the [ENTER] key.

7

BIDIRECTION
ADJUST

ADJUST
+0 +0

-20 to +20 (In steps of 1)

ADJUST
+0 +5