3.6 A-D Conversion Bypass Capacitor

There is a foot pattern on the M30850T-EPBM board for mounting bypass capacitors for the A-D
conversion circuit. Mount applicable bypass capacitors as occasion demands. Figure 3.8 shows
where they are installed.

IMPORTANT

Note on the A-D Converter:

• Because a converter board and other devices are used between the evaluation MCU

and the target system, the A-D converter operates differently from an actual MCU.
Make the final evaluation of the A-D converter using an actual MCU.

Figure 3.8 Foot pattern for the A-D conversion bypass capacitor

C1: V

REF

--AV

SS

bypass capacitor

C2: AV

CC

--AV

SS

bypass capacitor