Safety label, 4regency, E21-2 gas fireplace insert – Regency E21-NG2 User Manual
Page 4
4
Regency
®
E21-2 Gas Fireplace Insert
SAFETY LABEL
This is a copy of the label that accompanies
each Regency
®
Gas Insert. We have printed
a copy of the contents here for your review.
The safety label is located on the front inside
base of the unit visible when the bottom louver
is open.
Note: Regency
®
units are constantly being
improved. Check the label on the unit
and if there is a difference, the label
on the unit is the correct one.
Please note that with the addition
of thermostat control and outside
combustion air supply, this unit is
approved for bedroom installations.
Listed: VENTED GAS FIREPLACE HEA
TER
T
e
sted to:
ANSI Z21.88b-2003/CSA-2.33b-2003, CGA
2.17-M91
Gas
fi
red appliance for use at high altitude.
Certifi
ed for/Certifee pour: CANADA
and U.S.A. Report No. 476-1428-00 (DEC. 2000)
Model/
Modele:
DO NOT REMOVE THIS LABEL/ NE P
AS ENLEVER CETTE ÉTIQUETTE
296
Serial No./
No de Serie
918-488
Minimum Clearances to Combustibles/
Degagement Minimum Des Materiaux
Combustibles:
Side of unit to wall /
Cote:
A
9"/229mm
T
o
p of unit to
mantle /
Au dessus:
B 14"/355mm
MADE IN CANADA
/ F
A
BRIQUE
AU CANADA
FPI Fireplace Products International Ltd., Delta, B.C., Canada
FIREPLACE INSERT
:
E21-NG2
E21-LP2
APP
AREIL
FONCTIONNANT CONCU POUR
Natural Gas (Naturel Gaz)
Propane
ETRE INSERE DANS UN FOYER
Minimum supply pressure
5.0"
WC/C.E.
(1.25 kPa)
12.0"
WC/C.E.
(2.99 kPa)
Pression d’alimentation minimum
Manifold pressure high
3.8"
WC/C.E.
(0.95 kPa)
1
1
.0"
WC/C.E.
(2.74 kPa)
Pression tublure d'échappement élevée
Manifold pressure low
1.1"
WC/C.E.
(0.27 kPa)
2.9"
WC/C.E.
(0.72 kPa)
Pression tublure d'échappement basse
Altitude
0-2000 ft.
2000 - 4500 ft.
0-4500 ft.
L'altitude
(0 - 610m)
(610 - 1372m)
(0-1372m)
Orifi
ce size
43 DMS
44 DMS
54 DMS
Grandeur de l’injecteur
Maximum input
23,500 Btu/h
22,000 Btu/h
22,500 Btu/h
Debit calorifi
que
maximum
Minimum input
1
1
,750 Btu/h
1
1
,000 Btu/h
1
1
,250 Btu/h
Debit calorifi
que
minimum
Duplicate Serial No.
NOT FOR USE WITH SOLID FUEL. NE P
AS UTILISER
A
V
EC DU COMBUSTIBLE SOLIDE.
For installation into a vented non-combustible
fi
replace, listed factory built fi
replace. This vented
gas fi
replace heater is not for use with air fi
lters.
Ne peut etre installe que dans un foyer non
combustible muni d'un event. Ne pas utiliser de
fi
ltre à air avec ce foyer au gaz à évacuation.
W
A
RNING: This fi
replace has been converted for use
with a gas fi
replace insert only and cannot be used for
burning wood or solid fuels unless all original parts
have been replaced, and the fi
replace
re-approved
by
the authority having jurisdiction.
ELECTRICAL
SUPPL
Y/ALIMENT
A
TION
ELECTRIQUE:1
15V60HZ less than/Moins de 2
AMP
.
E21-NG2
E21-LP2
296
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.