beautypg.com

Safety label, 4regency, E21-2 gas fireplace insert – Regency E21-NG2 User Manual

Page 4

background image

4

Regency

®

E21-2 Gas Fireplace Insert

SAFETY LABEL

This is a copy of the label that accompanies
each Regency

®

Gas Insert. We have printed

a copy of the contents here for your review.
The safety label is located on the front inside
base of the unit visible when the bottom louver
is open.

Note: Regency

®

units are constantly being

improved. Check the label on the unit
and if there is a difference, the label
on the unit is the correct one.

Please note that with the addition

of thermostat control and outside
combustion air supply, this unit is
approved for bedroom installations.

Listed: VENTED GAS FIREPLACE HEA

TER

T

e

sted to:

ANSI Z21.88b-2003/CSA-2.33b-2003, CGA

2.17-M91

Gas

red appliance for use at high altitude.

Certifi

ed for/Certifee pour: CANADA

and U.S.A. Report No. 476-1428-00 (DEC. 2000)

Model/
Modele:

DO NOT REMOVE THIS LABEL/ NE P

AS ENLEVER CETTE ÉTIQUETTE

296

Serial No./

No de Serie

918-488

Minimum Clearances to Combustibles/

Degagement Minimum Des Materiaux

Combustibles:

Side of unit to wall /

Cote:

A

9"/229mm

T

o

p of unit to

mantle /

Au dessus:

B 14"/355mm

MADE IN CANADA

/ F

A

BRIQUE

AU CANADA

FPI Fireplace Products International Ltd., Delta, B.C., Canada

FIREPLACE INSERT

:

E21-NG2

E21-LP2

APP

AREIL

FONCTIONNANT CONCU POUR

Natural Gas (Naturel Gaz)

Propane

ETRE INSERE DANS UN FOYER

Minimum supply pressure

5.0"

WC/C.E.

(1.25 kPa)

12.0"

WC/C.E.

(2.99 kPa)

Pression d’alimentation minimum

Manifold pressure high

3.8"

WC/C.E.

(0.95 kPa)

1

1

.0"

WC/C.E.

(2.74 kPa)

Pression tublure d'échappement élevée

Manifold pressure low

1.1"

WC/C.E.

(0.27 kPa)

2.9"

WC/C.E.

(0.72 kPa)

Pression tublure d'échappement basse

Altitude

0-2000 ft.

2000 - 4500 ft.

0-4500 ft.

L'altitude

(0 - 610m)

(610 - 1372m)

(0-1372m)

Orifi

ce size

43 DMS

44 DMS

54 DMS

Grandeur de l’injecteur

Maximum input

23,500 Btu/h

22,000 Btu/h

22,500 Btu/h

Debit calorifi

que

maximum

Minimum input

1

1

,750 Btu/h

1

1

,000 Btu/h

1

1

,250 Btu/h

Debit calorifi

que

minimum

Duplicate Serial No.

NOT FOR USE WITH SOLID FUEL. NE P

AS UTILISER

A

V

EC DU COMBUSTIBLE SOLIDE.

For installation into a vented non-combustible

replace, listed factory built fi

replace. This vented

gas fi

replace heater is not for use with air fi

lters.

Ne peut etre installe que dans un foyer non

combustible muni d'un event. Ne pas utiliser de

ltre à air avec ce foyer au gaz à évacuation.

W

A

RNING: This fi

replace has been converted for use

with a gas fi

replace insert only and cannot be used for

burning wood or solid fuels unless all original parts

have been replaced, and the fi

replace

re-approved

by

the authority having jurisdiction.

ELECTRICAL

SUPPL

Y/ALIMENT

A

TION

ELECTRIQUE:1

15V60HZ less than/Moins de 2

AMP

.

E21-NG2

E21-LP2

296

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.