beautypg.com

Target foot pattern – Renesas Direct Dummy IC M3T-DIRECT100S User Manual

Page 3

background image

( 3 / 4 )

6. Target Foot Pattern

Figure 4 Target foot pattern

7. Recommended Procedure for Soldering the M3T-DIRECT100S

Unit: mm

Figure 5 Recommended procedure for soldering the M3T-DIRECT100S

(1) Fix the soldering position.

(2) Apply the flux.

(3) Solder.

Fix by solder tentatively.

• Apply the flux plenty to the half circle through holes of 4 sides.

• Use the soldering bit whose contact plane is wide.
• Move the soldering bit parallel with each plane (like sliding the

soldering bit).

• Take care not to push powerfully the half circle through hole.
• Check if there is not soldering bridge.

Note: The recommended foot pattern of the M3T-DIRECT100S is a common foot pattern for the 100P6S-A

and M3T-DIRECT100S. For the M3T-DUMMY100S, use the foot pattern recommended by Matsushita
Electric Works, Ltd. shown in the M3T-DUMMY100S User's Manual.