P36-4 Gas Log Fireplace

12

INSTALLATION

Simpson Dura-Vent

Co-Axial Flue GS

SIMPSON DURA-VENT FLUEING COMPONENTS LIST

All Simpson Dura-Vent components are available directly from Regency

®

.

Part # Description

Part # Description

Part # Description

SIMPSON DURA-VENT FLUEING

Horizontal or Vertical Terminations

The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations.
Many items are offered in decorative black, as well as galvanized fi nish. We recommend using the galvanized fi nish for installation with the P36.

The minimum components required for a basic
horizontal termination are:

1 Horizontal

Termination

Cap

1 90

o

Elbow

1 Flue

Adaptor

1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

971 Horiz. Termination Kit includes: 90

o

black elbow, wall thimble cover, horiz. square
termination cap, 24" black pipe, and 11" -14"
5/8" adjustable black pipe.
970 Basic Horiz. Termination. Kit includes:
90

o

black elbow, wall thimble cover, horiz.

square termination cap.

978 Vert. Termination Kit includes 0/12 -

6/12 pitch adjustable fl ashing, storm
collar, low profi le term. cap.

908B 6" Pipe Length - Black
907B 9" Pipe Length - Black
906

12" Pipe Length - Galv.

906B 12" Pipe Length - Black
904

24" Pipe Length - Galv.

904B 24" Pipe Length - Black
903

36" Pipe Length - Galv.

903B 36" Pipe Length - Black
902

48" Pipe Length - Galv.

902B 48" Pipe Length - Black
911B 11"-14 5/8" Adjustable Pipe Length

- Black

917B 17"- 24" Adjustable Length - Black
945 45

O

Elbow - Galv.

945B 45

O

Elbow - Black

945G 45

O

Elbow - Swivel - Galv.

945BG 45

O

Elbow - Swivel - Black

990 90

O

Elbow - Galv.

990B 90

O

Elbow - Black

990G 90

O

Elbow - Swivel - Galv.

990BG 90

O

Elbow - Swivel - Black

991 High

Wind

Termination

Cap

(Vertical)

980 Vertical

Termination

Cap

984

Horizontal Square Termination Cap

985

Horiz. Square High Wind

Termination

Cap

982

Snorkel - 14" Rise Termination Cap

981

Snorkel - 36" Rise Termination Cap

940

Wall Thimble - Support/Box

941

Cathedral/Ceiling - Support/Box

3951 Brass Trim for Wall Thimble/Ceiling

Sup.

963 Firestop

Spacer

943 Flashing

0/12-6/12

943S Flashing 7/12-12/12
953 Storm

Collar

950

Vinyl Siding Standoff

988 Wall

Strap

942 Wall

Thimble

Parts not supplied by Dura-Vent
946-506/P Flue

Guard

(Optional)

510-994 Dura-Vent

Flue

Adaptor

640-530/P Riser

Flue

Terminal

946-205 Vinyl

Siding Shield for Riser Flue

Terminal

If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2
inches.

Flat Wall Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

4" - 5-1/2"

6"

7" - 8-1/2"

9"

10" - 1-1/2"

12"

9" - 14-1/2"

11" - 14-5/8" Adj. Pipe

15" - 23-1/2"

17" - 24" Adj.

Corner Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

3-1/4" - 6-3/4"

11" - 14-5/8" Adj. Pipe

7-3/4" - 16-1/4"

17" - 24" Adj. Pipe

7-1/4" - 8-3/4"

6" + 12"

9" + 9"

4-1/4" - 5-3/4"

6" + 9"

Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl furring
strips may be used, instead of the vinyl siding
standoff, to create a level surface to mount the
fl ue terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.