( 6 / 12 )

(3) Set the MCU type selection switch (SW1) of the M38000TL2-FPD as shown in Table 4.2.

Table 4.2 Settings of the SW1 of the M38000TL2-FPD

Figure 4.2 Connecting the M38507ARLSS

4.2 Connecting to the Emulation Pod

(1) Insert the connector on the tip of the emulation pod probe to the socket on the emulator MCU.

(2) Connect the cables of the M38000TL2-PSW2 as shown in Table 4.1 depending on the emulator

MCU you use.

Do not connect the Vcc cable (yellow) to pin Vcc (TP1).

Table 4.1 Connector cables of the M38000TL2-PSW and applicable signals

Cable color

White

Black

Yellow

Signal

RESET

Vss

Vcc

For M38507ARLSS

TP3

TP2

TP1

For M38517RSS

TP3

TP2

No connection

M38507ARLSS

RLSS/RLFS

M38517RSS

RSS/RFS

M38000TL2-FPD SW1

(4) Connect a power supply (not included) to pin Vcc (TP1) of the M38517T-ADS. And connect the

GND output of the power supply to pin Vss (TP2). Use the power supply whose rising time is 10
ms or less.