4 dealer calibration, Leaving intermediate calibration, User calibration on/off – Raymarine ST60 Tridata User Manual
Page 51: Response settings

Calibration
39
Leaving Intermediate calibration
Hold down the
depth
and
speed
keys for 2 seconds, to save your settings,
exit Intermediate calibration and resume normal operation.
4.4 Dealer calibration
The Dealer calibration procedures enable the following parameters to be
set:
•
User calibration on/off.
•
Speed response.
•
Depth response.
•
Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This
enables you to re-apply the factory settings if you want to reset the
instrument to a known operating condition.
To commence Dealer calibration, hold down the
depth
and
speed
keys
together for approximately 12 seconds, to select the Dealer calibration
entry page (see Dealer calibration diagram). Then press the
trip
and
reset
keys together, to enter the calibration screen sequence.
Use the depth key to move from screen to screen and the trip or the rest
key to set the required values at each screen.
User calibration on/off
Press either the
trip
or
reset
key to toggle the User calibration on or off as
required. With off selected, User calibration and Intermediate calibration
are both disabled.
Response settings
The response values for both SPEED and DEPTH determine the frequency
at which information is updated. A low number provides a smooth
response and a high number a much livelier update.
Use the
trip
(decrement) and
reset
(increment) keys to set the required
value. Response values are from 1 to 15.