3 intermediate calibration – Raymarine ST60 Tridata User Manual
Page 46

34
ST60 Tridata Instrument Owner’s Manual
4.3 Intermediate calibration
Intermediate calibration enables you to:
•
Check the instrument software version.
•
Check the instrument status - either YES (master)) or NO (repeater).
You can also change the depth status, as required. This feature is par-
ticularly useful in preventing interference when using another prod-
uct (e.g. a fishfinder) that operates at 200 kHz.
•
Carry out a calibration run over a measured distance to ensure accu-
rate speed readings.
To start Intermediate calibration, hold down the
depth
and
speed
keys
for approximately 4 seconds (see Intermediate calibration flow chart).
To set the instrument status:
1. Press the
depth
key to select the Instrument status screen.
2. Press the
trip
and
reset
keys simultaneously to enter the depth adjust
mode, then press either
trip
or
reset
to set the required status, i.e.
either YES (for master operation) or NO (for repeater operation).
Note: You must not allocate more than one master depth instrument in
any system.
3. Press the trip and reset keys simultaneously again, to leave the adjust
mode.