1.8
Absolute Maximum Ratings
Rev.1.04 2008.07.10
1-11
REJ10J1564-0104
1
1.8 Absolute Maximum Ratings
Table 1.8.1 lists the absolute maximum rating of M3A-HS85.
Table 1.8.1 Absolute Maximum Ratings of M3A-HS85
Symbol Parameter Rated
Value
Remarks
5VCC
5V System Power Supply Voltage
-0.3V to 6.0V
Relative to VSS
3VCC 3.3V System Power Supply
Voltage
-0.3V to 4.6V
Relative to VSS
Topr
Operating Ambient Temperature
0°C to 50°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.
Tstr
Storage Ambient Temperature -10°C to 60°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.
Note: The ambient temperature refers to the air temperature in places closest possible to the board.
1.9 Recommended Operating Conditions
Table 1.9.1 lists the recommended operating conditions of M3A-HS85.
Table 1.9.1 Recommended Operating Conditions of M3A-HS85
Symbol Parameter Rated
Value
Remarks
5VCC
5V System Power Supply Voltage
4.5V to 5.5V
Relative to VSS
3VCC 3V System Power Supply Voltage
3.0V to 3.6V
Relative to VSS
-
Maximum Current Consumption in
the Board
Within 1A
Topr
Operating Ambient Temperature
0°C to 50°C
No dewdrops allowed.