5. Connection Procedure


5.1 For the M32170T-SDI or M32100T-SDI-E

(1) Mount the NQPACK144SD-ND on the user system

(2) Connect the YQPACK144SD on the NQPACK144SD-ND.

(3) Secure the four corners of the YQPACK144SD with the

YQ-GUIDEs.

Do NOT use the screws included with the
YQPACK144SD.

Do NOT use the screwdriver included with the
NQPACK144SD-ND for fixing the YQ-GUIDEs. That
is used only for the HQPACK144SD.

(4) Set the clock select switch.

Refer to "6. Selecting a Clock" on page 5.

(5) Mount the M32192T2-PTC on the YQPACK144SD.

(6) Mount the M3T-PTC-CNV on the M32192T2-PTC.

(7) Connect the emulation pod probe to the M3T-PTC-CNV

via the SDI MCU control interface cable and the SDI trace
interface cable.



Use a slotted screwdriver.

144-pin 0.5mm pitch
(144P6Q-A) foot pattern

(5)

(4) Clock select switch

(1)

(2)

(3)

(6)

(7) Interface cables

of the pod probe

M32192T2-PTC

YQPACK144SD

NQPACK144SD-ND

YQ-GUIDE(×4)

M3T-PTC-CNV
(separately available)

: No.1 pin
Be sure to match the position of No. 1 pin of
the foot pattern and each part.

Figure 5.1 Connection Procedure (1)