beautypg.com

Russound MCA-C5 User Manual

Page 21

background image

21

Russound MCA-C5 User and Installation Manual

Linked Controllers

MULTIpLE CONTROLLER INSTALLATION

Linking Multiple Controllers

The RNET Link In and Link Out can be used to connect two or more (up to 6)

MCA-C5 controllers (does not support CAV6.6, CAM6.6 or CAA66 controllers).

The connection is made using a CAT-5e patch cable from the Link Out of the

first controller and into the Link In of the next controller. Along with RNET data

signals, the RNET Link In and Link Out port passes source IR signals.

The CAT-5e patch cable must have an RJ-45 connector on each end with

T568A wiring configuration. It can not exceed 18 inches (45.7 cm) in length

to avoid potential cross-talk between the source-specific IR repeating signal

lines.

Controller ID Switch Settings

The Controller ID switch is a rotary switch with seven positions. It is used to set

the controller ID number for multi-controller systems, and to put the MCA-C5

into Firmware Update mode.

If two or more MCA-C5 controllers are connected using the RNET Link In and

Link Out ports, each controller must have a unique controller ID prior to being

connected through the RNET ports. Set each controller’s ID switch to a unique

number. Any multi-controller configuration requires that one controller be set

to controller ID #1. This action must be performed before the system setup

procedure is completed through SCS-C5 software and before powering up the

system. The small arrow on the dial should point at the desired setting.

MCA-C5 Controller (ID#2)

MCA-C5 Controller (ID#1)

CAT-5e Cable

Rotate switch to point arrow

to the intended position