(2) Errors Occur When Starting Up the Emulator Debugger

(When the target system is connected)

Table 5.2 Checkpoints of errors when starting up the emulator debugger (target is connected)

Error

Communication ERROR
Data is not sent to the target

Target system is not constructed properly

The version of M3T-PD30 and the firmware
on the target system are not same

Target MCU is reset state

Target MCU cannot be reset

Target MCU is in "HOLD" state

Target clock is stopped

Target MCU is not receiving power

Checkpoint

Check all emulator debugger settings, interface cable
connections and switches on the rear of the PC4701
match.

See the user's manuals of the PC4701 and emulator
debugger.

(1) Download the proper firmware.

See the user's manual of the emulator debugger.

(2) Recheck the connection between the M30200T-RPD-

E and this product.

See "3.3 Connecting the M30200T-RPD-E" (page 20).

(3) Recheck the connection between the PC4701 and

the M30200T-RPD-E.

See the M30200T-RPD-E User's Manual.

Download the proper firmware.

See the user's manual of the emulator debugger.

(1) Check the reset pin of the target system is pulled up.
(2) Check the reset pin of the target system has changed

from "L" to "H" level.

(1) If the reset circuit of the target system has a watchdog

timer, disable the timer.

(2) Check power is properly supplied to the target system

and that the target system is properly grounded.

The MCU is either in the stop mode or wait mode. Either
reset the MCU or cancel the mode with an interrupt.

See MCU specifications.

(1) Check the oscillation circuit in the target system is

oscillating properly.

(2) Check the switches of the FLX64-PRB are correctly

set.

See "3.1 Switch Settings" (page 18).

Check power is properly supplied to the target system
and that the target system is properly grounded.