Specifications
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Model
V53i
V53e
Minimum Gas Consumption Btu/h
15,000
20,200 (LP) 19,000 (NG)
Maximum Gas Consumption Btu/h
150,000
120,000
Hot water capacity (Min - Max) *
Hot water capacity (45°F rise)
5.3 GPM (20.0 L/min)
4.2 GPM (16.0 L/min)
Temperature Settings (without temperature
controller)
120º F (49º C), default or 140º F (60º C)
Temperature Controller Default Setting
104º F (40º C)
Maximum Temp Setting (residential)
see Temperature Ranges for more information
140º F (60º C)
Minimum Temperature Setting
98º F (37º C)
Weight
51 lb (23.0 kg)
34.2 lb (15.5 kg)
Efficiency Rating
84.0%
82.0%
Noise level
49 dB
Electrical Consumption
Normal
55 W
33 W
Standby
2 W
Anti-frost Protection
184 W
74W
By-Pass Control
Fixed
Minimum Gas Supply
Pressure
Natural Gas
5.0 inch W.C.
Propane
8.0 inch W.C.
Maximum Gas Supply
Pressure
Natural Gas
10.5 inch W.C.
Propane
13.5 inch W.C.
Type of Appliance
Temperature controlled continuous flow gas hot water system.
Operation
With or without temperature controller, mounted in kitchen, bathroom, etc.
Approved Gas Type
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.
Connections
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System
Direct Electronic Ignition
Electric Connections
Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward and Feedback.
Water Supply Pressure
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Remote Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
Energy Star Qualified
Yes
Certified for installation in manufactured
(mobile) homes
Yes
0.6 - 5.3 GPM (2.4 - 20.0 L/min)