beautypg.com

Warning, Freeze protection methods – Rinnai V53I User Manual

Page 22

background image

22

V53i & V53e Operation and Installation Manual

If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the
water inside the water heater be drained.

To manually drain the water:
1. Shut off cold water supply and gas supply.
2. Turn off the temperature controller.
3. Disconnect the power to the water heater.
4. Open hot water tap or open hot water drain plug at the

hot water outlet.

5. Remove water filter to drain the cold water.

Freeze

Protection

Methods

Manual draining of the water heater

WARNING

To avoid burns, wait until the equipment cools down before draining the water. The
water in the appliance will remain hot after it is turned off.

To resume normal operation:
1. Confirm that all water drain plugs are removed, that

the gas supply is turned off, and that all taps are
closed.

2. Screw in the hot water drain plug.
3. Screw in the water filter in the cold water inlet.
4. Open the cold water supply.
5. Open a tap and confirm that water flows, and then

close.

6. Turn on the power.
7. After confirming that the temperature controller is off,

turn on the gas supply.

8. Turn on the temperature controller.

Running a low volume of water through the water heater to prevent freezing

If the temperature exceeds the ability of the water heater to freeze
protect itself, or if power is lost, the following steps may prevent the
water heater and external piping from freezing. (Units connected with
MSA or EZConnect should be drained to prevent freezing if not in
use.)
1. Turn the water heater off.
2. Close the gas supply valve.
3. Reduce the flow to about 0.1 gal/min or to where the stream is

about 0.2 inches thick.

When the water heater or external piping has frozen

1.Do not operate the water heater if it or the external piping is frozen.

2.Close the gas and water valves and turn off the power.

3.Wait until the water thaws. Check by opening the water supply valve.

4.Check the water heater and the piping for leaks.

HOT

COLD

ON!

0.1 gal/min or
about 0.2 inch
thick

* Use a wrench or other
tool to unscrew the hot
water drain plug.

Water
filter

Hot water
outlet

Hot water
drain plug *

Cold water
inlet

This manual is related to the following products: