beautypg.com

Troubleshooting – RIDGID OL50145MW User Manual

Page 17

background image

7

TROUbLESHOOTING

PRObLEM

CAUSE

SOLUTION

Compressor will not run

Loss of power or overheating

No electrical power

Blown shop/house fuse
Shop/house breaker open

Thermal overload open
Pressure switch bad
Tank is full of air

Check for proper use of extension
cord
Check to be sure unit is plugged in
Check fuse/breaker
Replace shop/house blown fuse
Reset shop/house breaker, determining
why problem happened
Motor will restart when cool
Replace pressure switch
Compressor will turn on when tank
pressure drops to cut-in pressure

Motor hums but cannot run or runs
slowly

Low voltage
Wrong gauge wire or length of exten-
sion cord
Shorted or open motor winding
Defective check valve or unloader

Check with voltmeter
Check for proper gauge wire and cord
length
Take compressor to service center
Take compressor to service center

Thermal overload protector cuts out
repeatedly

Low voltage
Lack of proper ventilation/room tem-
perature too high
Wrong gauge wire or length of exten-
sion cord

Check with voltmeter
Move compressor to well-ventilated
area
Check for proper gauge wire and cord
length

Air tank pressure drops when compres-
sor shuts off

Loose connections (fittings, tubing,
etc.)
Loose drain valve
Check valve leaking

Check all connections with soap and
water solution and tighten
Tighten drain valve
Take compressor to service center

DANGER:

Do not disassemble check valve,
tank drain valves or safety relief valve
with air in tank — bleed tanks.

Excessive moisture in discharge air

Excessive water in air tanks
High humidity

Drain tanks
Move to area of less humidity; use air
line filter

Compressor runs continuously

Defective pressure switch
Excessive air usage

Piston rings are worn

Take compressor to service center
Decrease air usage; compressor not
large enough for tool’s requirement

Replace piston rings; Call customer
service for assistance

Air output lower than normal

Broken inlet valves
Connections leaking

Take compressor to service center
Tighten connections