beautypg.com

Maintenance, Valve assembly replacement – Regency Sunrise U32S-NG5 User Manual

Page 28

background image

28

U32S-5 FPI Direct Vent Gas Insert

1) Turn the unit off and allow it to cool down to room temperature.

2) Disconnect the power source and turn off the gas supply to the
insert.

3) Open the bottom louver.

4) Remove the door frame by lifting out from the bottom and lift up off

the glass door.

5) Remove the glass door.

a) Remove the 2 hooks shown below at the bottom of the glass

door

.

b)

Swing the door out 45

o

from the bottom and lift up and

out.

6) Remove the burner by undoing the 2 screws shown. Carefully slide

the burner to the left. Then lift the burner up and out ensuring not to
spill glass crystals.

7) Carefully set aside the burner and glass crystals.

Door Frame

Glass Door

Burner

VALVE ASSEMBLY REPLACEMENT

8) Remove the base cover by lifting up from the back and maneover

out.

Base Cover

9) Disconnect the ON/OFF connector wires from the valve.

NOTE: For LP units disconnect the DC Sparker ignitor wire from the
valve.

ON/OFF Wires

MAINTENANCE