beautypg.com

Installation, Fig.2 fig.3, Fig.4 – Regency Sunrise U32S-NG5 User Manual

Page 12

background image

12

U32S-5 FPI Direct Vent Gas Insert

INSTALLATION

WARNING!

Do not overtighten the screw.

Recommended to grip

the wrench by the short side.

13) Turn control knob to the “OFF” position.

14) Remove the black protection cap by

hand from the high-low knob (Fig.1).

15) Insert a 5/32” or 4mm Allen wrench into

the hexagonal key-way of the screw
(Fig. 2), rotate it counter-clockwise until
it is free and extract it.

16) Check that the screw is clean and if

necessary remove dirt.

17) Flip the screw (Fig. 3).

18) Using the Allen wrench as shown in

Fig.4, rotate the screw clockwise until
snug, do not overtighten.

19) Verify that if the conversion is from

NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).

20) Re-assemble the black protection cap

(Fig. 6).

WARNING!

Also check that the pilot and

main burner injectors

are appropriate for the gas type.

Fig. 1

Fig.2

Fig.3

Fig.4

LPG Configuration

Red o-ring visible

Fig.5

Fig. 6

9)

Pull off the pilot cap to expose the pilot

orifi

ce.

10) Unscrew the pilot orifi ce with the
supplied allen key and replace it with the

LP pilot orifi ce and re-install the pilot cap
and the pilot shield.

11) Re-install base cover.

12) Re-install the burner.

NOTE: Before re-installing the burner,
ensure the LP areation setting is set
at 1/2" min. when using glass crystals

and 1/8" min. when using ceramic

stones.

21) See DC Sparker installation in the

instruction manual.

22) Attach the label "This unit has been

converted to LPG" near or on top of the
serial # decal.

23) Replace yellow "NG" label with red

"LPG" label.

24) Check for gas leaks.

25) Check inlet and outlet pressures.

26) Reverse Step 2.

27) Check operation of fl ame control.

Pilot Cap

Installer Notice:

These instructions must be left

with the appliance.

This manual is related to the following products: