beautypg.com

3 inserting cable head, 4 fastening cable head, Caution – Renesas H8SX/1520 User Manual

Page 10

background image

6

2.2.3

Inserting Cable Head

CAUTION

Check the location of pin 1 before inserting.

Align pin 1 on the IC socket for an FP-100M package on the user system with pin 1 on the user
system interface cable head, and insert the user system interface cable head into the IC socket on the
user system, as shown in figure 3.

2.2.4

Fastening Cable Head

CAUTION

1. Use a Philips-type screwdriver whose head matches

the screw head.

2. The tightening torque must be 0.0785 N•m or less.

If the applied torque cannot be accurately measured,

stop tightening when the force required to turn the screw

becomes significantly greater than that needed when first

tightening. If a screw is tightened too much, the screw

head may break or an IC socket contact error may be

caused by a crack in the IC socket solder.

3. If the emulator does not operate correctly, cracks might

have occurred in the solder. Check conduction with

a tester and re-solder the IC socket if necessary.