How to Set the Temperature

DANGER

Hot water can be dangerous, especially for infants or children, the elderly,
or infirm. There is hot water scald potential if the thermostat is set too high.

Water temperatures over 125º F (51º C) can cause severe burns or
scalding resulting in death.

Hot water can cause first degree burns with exposure for as little as:

3 seconds at 140º F (60º C)

20 seconds at 130º F (54º C)

8 minutes at 120º F (48º C)

Test the temperature of the water before placing a child in the bath or
shower.

Do not leave a child or an infirm person in the bath unsupervised.

Temperature Controller Settings

This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied
or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time.
The available temperatures for a given model are provided below.

Model

RL75e

98 100 102 104 106 108 110 115 120

125

*

130

*

135

*

140

*

150

**

160

**

RL94e

R98LSe

R98LSe-ASME

98 100 102 104 106 108 110 115 120

125

*

130

*

135

*

140

*

150

**

160

**

185

**

Temp in Celsius ºC

37

38

39

40

41

42

43

46

49

52

54

57 60

66

71

85

Temperature Settings Available (ºF)

While any hot water is being provided,
the temperature setting can only be
adjusted between 98º F and 110º F.

NOTICE

Check local codes for the maximum
water temperature setting allowed
when used in nursing homes, schools,
day care centers, and all other public
applications.

NOTICE

If a newly installed unit with a
controller has not been powered for at
least 6 hours then the temperature will
return to the default setting of 104º F
(40º C) if power is interrupted.

NOTICE

There may be a variation between the
temperature displayed on the
temperature controller and the
temperature at the tap due to weather
conditions or the length of pipe to the
water heater.

NOTICE

1. If the water heater is off, press

the ON/OFF button to turn on.

The priority can only be changed
while no hot water is running.

2. Press the “Priority button” on the

temperature controller. The
green Priority light will glow
indicating that this controller is
controlling the temperature and
that the Rinnai water heater is
ready to supply hot water.

3. Press

the

▲ or ▼ buttons to

obtain the desired temperature
setting.

All hot water sources are able to
provide water at this temperature
setting until it is changed again at
this or another temperature
controller.

An older controller, MC-45, can be installed with the RL75e, RL94e, R98LSe, and R98LSeASME by moving dip
switch No. 6 in the bank of 6 dip switches to ON. Some of the temperature settings will be slightly different from
the above table.