VB Series Outdoor LS Manual

29

High

Altitude

Installations

0-2000 ft

(0-610 m)

2001-5200 ft

(610-1585 m)

5201-7700 ft

(1585-2347 m)

7701-10200 ft

(2347-3109 m)

Switch No. 2

OFF

OFF

ON

ON

Switch No. 3

OFF

ON

OFF

ON

Set dip switches 2 and 3 to the values shown in table
below for your altitude. The default setting for the
appliance is 0-2000 ft (0-610 m) with switches No. 2
and No. 3 in the OFF position.

Connecting Multiple Water Heaters

WARNING

DO NOT adjust the other dip
switches unless specifically
instructed to do so.

Switch No.

F

O

F

8

5

7

6

4

3

ON

1

2

Switch No.

F

O

F

8

5

7

6

4

3

ON

1

2

Switch No.

F

O

F

8

5

7

6

4

3

ON

1

2

Switch No.

F

O

F

8

5

7

6

4

3

ON

1

2

The EZConnect™ cable is an optional accessory
that connects 2 water heaters and allows them to
function as one hot water source.

The MSA-2M and MSA-2S packs are optional
accessories that connect 2 to 5 water heaters
and allow them to function as one hot water
source.

Refer to the instructions that come with the
accessory for complete installation information.

Number of

Connected

Water Heaters:

Accessories Necessary:

2

(1) EZConnect™ Cable

or

(1) MSA-2M

3

(1) MSA-2M

and

(1) MSA-2S

4

(1) MSA-2M

and

(2) MSA-2S

5

(1) MSA-2M

and

(3) MSA-2S

Guidelines

• Do not install both the EZConnect™ and the

MSA packs because they are not designed to
operate together.

• Water heaters connected with the

EZConnect™ Cable or the MSA-2M and MSA-
2S packs cannot be used for the bath fill
function.

• Water heaters should be installed less than 18

inches apart so that the cables will reach
between units and to prevent temperature
fluctuations (cold water sandwich effect) when
the water is shut off and turned back on.

• Temperature settings can only be changed on

the controller for the primary unit.

Model

Number of units
in standby

Position of dip switch No. 5
in bank of 6 dip switches

RL75,

RL94

1

Dip switch No. 5 is ON

2

Dip switch No. 5 is OFF
(default)

R98LS 2 Not

applicable