Specifications – Rinnai RL75E User Manual
Page 3
VB Series Outdoor LS Manual
3
Specifications
Model
RL75e
RL94e
R98LSe
R98LSe-ASME
Minimum Gas Consumption Btu/h
9,900 (NG)
10,300 (LPG)
19,000
Maximum Gas Consumption Btu/h
180,000
199,000
237,000
Hot water capacity (Min - Max) *
0.4 - 7.5 GPM
(1.5 - 28.5 L/min)
0.4 - 9.4 GPM
(1.5 - 35.5 L/min)
0.6 - 9.8 GPM
(2.3 - 37 L/min)
Hot water capacity (45°F rise)
6.6 GPM
(25.1 L/min)
7.1 GPM
(27.0 L/min)
8.5 GPM
(32 L/min)
Default Temperature Setting (no controller)
120º F (49º C)
Temperature Controller Default Setting
104º F (40º C)
Maximum Temp Setting (commercial **)
160º F (71º C)
185º F (85º C)
Maximum Temp Setting (residential)
see Temperature Ranges for more information
Selectable at 120º F (49º C) or
at 140º F (60º C)
140º F (60º C)
Minimum Temperature Setting
98º F (37º C)
Weight
51 lb (23 kg)
55 lb (25 kg)
Efficiency
Energy Factor: 0.82
Thermal Efficiency: 83.0%
Noise level
49 dB (A)
Electrical
Consumption
Normal
44 W
49 W
72 W
Standby
2 W
Anti-frost Protection
104 W
116 W
By-Pass Control
Fixed
Electronic
Minimum Gas
Supply
Natural Gas
5.0 inch W.C.
Propane
8.0 inch W.C.
Maximum Gas
Supply
Natural Gas
10.5 inch W.C.
Propane
13.5 inch W.C.
Type of Appliance
Temperature controlled continuous flow gas hot water system.
Operation
With or without temperature controls, mounted in kitchen, bathroom, etc.
Approved Gas Type
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.
Connections
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System
Direct Electronic Ignition
Electric Connections
Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward and Feedback.
Water Supply Pressure
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Temperature Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
Energy Star Qualified
Yes
Yes
No
No
Certified for installation in manufactured
(mobile) homes
Yes
Yes
No
No
Energy Factor: 0.82
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for
the purpose of input adjustment.
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
** for commercial and hydronic applications requiring higher temperatures