APPENDICES

APPENDICES-27

M32R-FPU Software Manual (Rev.1.01)

(4) When Inexact Operation Exception occurs in Step 1

If an Inexact Operation occurs due to rounding:

Type of R0

Condition

FMUL + FADD Operation

FMADD Operation

Normalized

R0 = rounded value of

Same as left

number, 0,

R1*R2 + R0

Infinity

Denormalized

DN=0

UIPL occurs, EIT occurs

Same as left

number

R0 = maintained

DN=1

R0 = rounded value of

Same as left

R1*R2

QNaN

R0 = maintained (QNaN)

Same as left

SNaN

EV=0

IVLD occurs

Same as left

R0 = R0 converted to QNaN

EV=1

IVLD occurs, EIT occurs

Same as left

R0 = maintained (SNaN)

Type of R0

Condition

FMUL + FADD Operation

FMADD Operation

Normalized

EIT occurs when FMUL is

EIT occurs,

number, 0,

completed

R0 = maintained

Infinity

R0 = maintained

Denormalized

DN=0

Same as above

UIPL occurs,

number

EIT occurs

R0 = maintained

DN=0

Same as above

EIT occurs

R0 = maintained

QNaN

Same as above

Same as above

SNaN

EV=0

Same as above

IVLD occurs,

EIT occurs

R0 = maintained

EV=1

Same as above

Same as above

When an Inexact Operation occurs due to an OVF at EO = 0:

Refer to “(1) Overflow occurs in Step 1 ”.

Same results as “

If an Inexact Operation occurs due to rounding

occurs>”.

APPENDIX 6

Appendix 6 M32R-FPU Specification Supplemental Explanation