4 user calibration options, How do i access user calibration settings, Autotack angle (sailboat only) – Raymarine ST7002 User Manual
Page 33: User calibration pages
Chapter 2: Advanced Operation
23
2.4 User Calibration Options
The calibration information in this handbook relates to only those settings that
can be adjusted during normal operation (USER CAL). For information on all
available calibration settings, see
SmartPilot Commissioning Guide.
Note:
Many of the settings are sailboat specific and will only be displayed if your vessel
type is set to
SAILBOAT
.
How do I access User Calibration settings?
You can only access the calibration mode from Standby mode:
1. With the SmartPilot in Standby mode, press and hold the standby button for
2 seconds. The display will change to show DISPLAY CAL.
2. Press the disp button once, the display will now show USER CAL.
3. Press auto to enter User Calibration.
The first page of User Calibration will now be displayed.
4. To access other User Calibration pages, press disp to scroll down through the
items within that grouping:
5. When you reach an item you wish to adjust, use the -1, +1, -10 and +10 but-
tons (as appropriate) to change the value.
6. When you have made all the changes you want to make, press and hold
standby for two seconds to exit calibration mode and save changes.
User Calibration pages
AutoTack angle (SAILBOAT only)
The AutoTack angle is the angle through which the boat will turn when you select
an automatic tack.
Screen Text
Options
AUTO TACK
40° to 125° in 1° steps