beautypg.com

Section 3 verifying operation – Renesas User System Interface Board HS1650ECN61H User Manual

Page 23

background image

12

Section 3 Verifying Operation

1. Turn on the emulator according to the procedures described in the H8SX/1650 Series E6000H

Emulator User's Manual (HS1650EPH60HE).

2. Verify the user system interface cable connections by checking the pin states with the CHECK

command (emulator command) and checking the bus states with the FILL command (emulator
command). If an error is detected, recheck the soldered IC socket and the location of pin 1.

3. The emulator connected to this user system interface board supports three kinds of clock sources

as the MCU clock. For details, refer to the H8SX/1650 Series E6000H Emulator User's Manual
(HS1650EPH60HE).

To use the emulator internal clock
Select the clock in the emulator by the CLOCK command (emulator command).

To use the external clock on the user system
Supply the external clock from the user system to the emulator by inputting the EXTAL pin
(pin 84) on the user system interface board or connecting the crystal oscillator to the XTAL
(pin 83) and EXTAL pins. For details, refer to the H8SX/1650 Hardware Manual.

Figure 8 shows the clock oscillator on the user system interface board.

270

0

1 M

HCU04

HCU04

HCU04

HCU04

EXTAL XTAL

HCU04

To E6000H
emulator

HCU04

System clock

Figure 8 Clock Oscillator