11. Technical Data
Table 8
Description
Value
Remarks
Protective heights
120 mm to 1920mm
120mm increments
Operating range
0 ... 9 m
Resolution 14 mm
0 ...6m
Resolution 30 mm
Object detection capability
14 mm
(Resolution)
30 mm
Power supply U
sp
24 VDC ± 20 %
PELV, IEC 60 204-1
Power supply ripple
< 10 % of U
sp
Equipment Class
III
VDE 0106 part 100
Time for self check when switching on U
sp
< 3 s
Current consumption
< 500 mA
No-load operation
Outputs, short circuit proof
2 x PNP, 0.3 A
Max. capacitive load 0.5 µF
Output voltage
> U
sp
– 1
Load 0.1 A
Response time t
R-BWS
Selection table
Page 18
Connector
M12 qd
Connection cable
Max length 5 m
Cross section max. 1.5 mm
2
Outside diameter of cable
3 ... 6.5 mm
for M12
Mode of operation
Guard only with automatic restart
Safety category
Type 4
Self testing
Standards
IEC 61496 part1+2
Electromagnetic compatibility (EMC)
IEC 61 496 part 1
Enclosure rating
IP65
Temperature range
0 ... +55°C
Operation with ILAS
-20 ... +60°C
Storage / transport
Relative air humidity
15 ... 95 %
Non condensing
Enclosure
Aluminum profile 30 x 40 mm
Optical window
Polycarbonate, bonded
Enclosure treatment
Polyester powder coated
Silicon free manufactured
ILAS
Laser class 2
EN 60 825
Dimensions
Dimensions and selection tables
Page 17 + 18
Weight
Selection tables
Page 18
PAC operating range
0 - 30m
2 and 3 segments