Set configuration switches, Figure 2-2. factory default switch settings, Set configuration switches -4 – National Instruments GPIB-BUF User Manual
Page 19: Figure 2-2. factory default switch settings -4, Table 2-1
Installation and Operation
Chapter 2
GPIB-BUF User Manual
2-4
© National Instruments Corp.
Set Configuration Switches
Use the DIP switch at location U38 on the printed circuit board to configure
the GPIB primary address and operating modes of the GPIB-BUF. The DIP
switch has eight configuration switches. Figure 2-2 shows the factory
default setting.
O
N
O
F
F
Key
= depressed side of switch handle
1
2
3
4
5
6
7
8
Figure 2-2. Factory Default Switch Settings
Table 2-1 and Table 2-2 detail the possible configurations of the eight
switches and what each configuration indicates. For more information on
the different operating modes configured by the switches, refer to
Chapter 3, Technical Information .
Default settings are in shaded rows.
Table 2-1. Configuration Parameters for Switches 1 through 3
Switch
Position
Indication
1
OFF
Enables device clear recognition
ON
Disables device clear recognition
2
OFF
Sends DCL to the target and resets the
GPIB -BUF
ON
Sends DCL to the target
3
OFF
Disables SRQ on buffer empty
ON
Enables SRQ on buffer empty