beautypg.com

Set configuration switches, Figure 2-2. factory default switch settings, Set configuration switches -4 – National Instruments GPIB-BUF User Manual

Page 19: Figure 2-2. factory default switch settings -4, Table 2-1

background image

Installation and Operation

Chapter 2

GPIB-BUF User Manual

2-4

© National Instruments Corp.

Set Configuration Switches

Use the DIP switch at location U38 on the printed circuit board to configure
the GPIB primary address and operating modes of the GPIB-BUF. The DIP
switch has eight configuration switches. Figure 2-2 shows the factory
default setting.

O
N

O

F
F

Key

= depressed side of switch handle

1

2

3

4

5

6

7

8

Figure 2-2. Factory Default Switch Settings

Table 2-1 and Table 2-2 detail the possible configurations of the eight
switches and what each configuration indicates. For more information on
the different operating modes configured by the switches, refer to
Chapter 3, Technical Information .

Default settings are in shaded rows.

Table 2-1. Configuration Parameters for Switches 1 through 3

Switch

Position

Indication

1

OFF

Enables device clear recognition

ON

Disables device clear recognition

2

OFF

Sends DCL to the target and resets the
GPIB -BUF

ON

Sends DCL to the target

3

OFF

Disables SRQ on buffer empty

ON

Enables SRQ on buffer empty