100 Mb Fiber Transceiver Characteristics
Fiber Length
2km*
15km**
40km**
80km**
TX Power Min/Max
-19dBm/-14dBm
-15dBm/-7dBm
-5dBm/0dBm
-5dBm/0dBm
RX Sensitivity Max
-32dBm
-29dBm
-34dBm
-34dBm
Wavelength Min/Max
1310nm
1310dm
1310dm
1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Gigabit Fiber Transceiver Characteristics
Fiber Length
550m* with
50/125 µm
300m* with
62.5/125 µm
10km**
40km**
70km**
TX Power
Min/Max
-9.5dBm/-4dBm
-9.5dBm/-4dBm
-5dBm/0dBm
-4dBm/1dBm
-3dBm/2dBm
RX Sensitivity
Max
-17dBm
-17dBm
-20dBm
-21dBm
-23dBm
Wavelength
850nm
850nm
1310nm
1550nm
1550nm
Assumed
Fiber Loss
-3.5 dB/km
-3.75 dB/km
-0.5 dB/km
-0.25 dB/km
-0.20 dB/km
Laser Type
VCSEL
VCSEL
FP
DFB
DFB
*SX Fiber Optic Cable
** LX Fiber Optic Cable
Regulatory Approvals:
Safety: UL 1604 (US and Canada) Hazardous Locations, Class I, Div 2, Groups A, B, C, D, T4A
EMI:
EN61000-6-4, EN55011 – Class A
FCC Title 47, Part 15, Subpart B - Class A
EMS: EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Conducted Low Frequency: IEC60533
Shock:
IEEE 1613 (250 mm)
Vibration:
IEEE 1613 (V.S.3 20 mm/s)
IEC60068-2-6 (Test Fc)
Cold:
IEC60068-2-1
Dry Heat:
IEC60068-2-2
Damp Heat:
IEC60068-2-30 (Test Db)