INSTALL ELECTRICAL

WARNING: Electrical wiring must be

done by a qualified person(s) in accor-
dance with all applicable codes and stan-
dards. This range hood must be prop-
erly grounded. Turn off electrical power
at service entrance before wiring.

1. Plan where the hood will be located above

the cook top. Refer to the “INSTALL MOUNT-
ING BRACKET” section for hood mounting
height options.

2. Install a standard 2” x 4” wall outlet box and

3-blade 125 volt, 15Amp grounded recep-
tacle.

3. Mount the receptacle 18” to 22” above the

bottom of the hood.

4. Locate the receptacle within boundary shown

and off center of the ductwork (to allow for
power cord plug and flue clearance).

INSTALL THE DUCTWORK

(DUCTED HOODS ONLY)

!

CAUTION: To reduce the risk of fire, use

only metal ductwork.

1. Decide where the ductwork will run be-

tween the hood and the outside.

2. A straight, short duct run will allow the hood

to perform most efficiently.

3. Long duct runs, elbows, and transitions will

reduce the performance of the hood. Use as
few of them as possible. Larger ducting may
be required for best performance with longer
duct runs.

4. Install a roof or wall cap. Connect round metal

ductwork to cap and work back towards hood
location. Use duct tape to seal the joints be-
tween ductwork sections.

CENTER LINE
OF HOOD AND
DUCT

24” TO 30” ABOVE

COOKING SURFACE

(See “INSTALL MOUNTING

BRACKET” section for

mounting restrictions)

HOOD

ROOF CAP

6”

ROUND DUCT

WALL

CAP

ROUND
ELBOW

6”

ADAPTER

DECORATIVE

FLUE