PREPARE THE HOOD

NOTE: On stainless steel hoods, carefully
remove the plastic protective film from all
exterior surfaces of the hood, decorative
flues, and filter trames prior to final instal-
lation.

(DUCTED HOODS ONLY)

1. Install the discharge collar into the duct

connector of the range hood.

2. Attach an adequate length of 6” round steel

ducting to the range hood duct connector.

3. Duct tape all joints to make them secure

and air tight.

4. Secure the electrical system plate to the

range hood with (2) mounting screws.

5. Carefully place the lower decorative flue

into the recessed area of the range hood
top.

6. Carefully slide the upper decorative flue

down inside the lower flue.

Note: On 8-foot ceilings the air vents on the
upper flue are concealed by installing the flue
with air vents down.

Note: On 9-foot ceilings the air vents on the
upper flue will be exposed after installation.

ROOMS WITH 10-FOOT CEILINGS
Rooms with 10-foot ceilings require flue ex-
tension model RFX5304, available from your
local dealer.

7. Discard the upper flue supplied with the

product. Replace it with the flue extension
RFX5304.

D I S C H A R G E

C O L L A R

6 ”

D I A M E T E R

D U C T

DUCT

CONNECTOR

3.9 x 9.5mm
SCREWS

E L E C T R I C A L

S Y S T E M

PLATE

UPPER
FLUE

LOWER
FLUE

UPPER FLUE

VENTS

EXPOSED

(9 foot

ceiling)

UPPER FLUE

VENTS

CONCEALED

(8 foot
ceiling)