FUSE REPLACEMENT

IF LIGHTS FAIL TO OPERATE, DISCON-
NECT POWER AT THE SERVICE EN-
TRANCE. CHECK THE FUSE AND RE-
PLACE IF NECESSARY.

1. Raise or remove the lower decorative flue.

2. Remove the cover from the fuse box.

3. Unscrew the cap from the fuse holder and

remove the fuse.

4. Replace the fuse with the same size and

amperage (5 x 20mm, 4 amp, 125 volt).

Do not use fuses greater than 4 amps.
Fuses greater than 4 amps may dam-
age the transformer.

5. Reinstall the fuse holder cap, fuse box

cover and flue.

6. Reconnect power at the service entrance.

MAINTENANCE

Proper maintenance of the Range Hood will
assure proper performance of the unit.

Grease Filters
The grease filters should be cleaned fre-
quently. Use a warm detergent solution.
Grease filters are dishwasher safe.

See “INSTALL FILTERS” section for removal
and installation instructions.

Non-Ducted Recirculation Filter
The non-ducted recirculation filter should be
changed every 6 months.

See “INSTALL FILTERS” section for removal
and installation instructions.

NON-DUCTED

RECIRCULATION

FILTER

FUSE

FUSE
BOX

DECORATIVE
FLUE

GREASE FILTERS