PREPARE THE HOOD

(NON-DUCTED HOODS ONLY)

Note: The following materials must be purchased separately for non-ducted recircu-
lation installations.

Non - Ducted Recirculation Kit, Model RRK51.
5” diameter expandable / flexible aluminum duct.
1/16” diameter twist drill.

!

CAUTION: Do not use plastic or rigid metal ducting.

1. Determine the length of the compressed flexible aluminum ducting using the

following formula:

2. Discard the discharge collar/damper

supplied with the hood. Install the 5” to
6” adapter supplied with the Non-Ducted
Recirculation Kit.

3. Attach aluminum flexible duct to the 5”

adapter. Securely tape all joints with
duct tape to prevent separation of com-
ponents as flex ducting is expanded.

4. Assemble the recirculation plenum to

the flexible duct.

5. Drill three (3) 1/16” diameter equally

spaced holes through the duct and duct
connector of the recirculation plenum.

6. Secure duct to the plenum’s connector

with (3) sheet metal screws: (3.9 x9.5
mm) Tape all joints with duct tape.

7. Secure electrical system plate to the

range hood with (2) mounting screws.

3.9 x 9.5mm
SCREWS

ELECTRICAL
SYSTEM
PLATE

PLENUM

5” to 6”
ADAPTER

BLOWER
COLLAR

5” ALUMINUM
FLEX DUCT

3 SCREWS

34” MINUS

Distance above
cook top. See Page
9, height restrictions
table.

PLUS 12” If ceiling

height is 9-
feet. (or 24” If
ceiling height
is 10 feet)

= Length of compressed

flexible aluminum
ductwork.

Worksheet: 34” - __________ + ___________ (for 9’ or 10’ ceiling only) = __________