2.3 GENERAL

INFORMATION

2.4 RATING PLATE INFORMATION

BGNV40

NG

LP

Altitude (FT)

0-4,500

0-4500

Max. Input (BTU/HR)

30,000

30,000

Max. Output (BTU/HR)

20,400

Effi ciency (w/the fan on)

68%

Min. Inlet Gas Supply
Pressure

4.5" Water Column

11" Water Column

Max. Inlet Gas Supply
Pressure

7" Water Column

13" Water Column

Manifold Pressure (Under
Flow Conditions)

3.5" Water Column

10" Water Column

When the appliance is installed at eleva-
tions above 4,500ft, and in the absence of
specifi c recommendations from the local
authority having jurisdiction, the certifi ed
high altitude input rating shall be reduced
at the rate of 4% for each additional
1,000ft. Expansion / contraction noises
during heating up and cooling down cycles
are normal and to be expected.

This appliance is approved for bedroom
and bed-sitting room installations and is
suitable for mobile home installation.

NO EXTERNAL ELECTRICITY (110 VOLTS OR 24 VOLTS) IS REQUIRED FOR THE GAS SYSTEM OPERA-
TION
.

FOR YOUR SATISFACTION, ALL BURNER ASSEMBLIES HAVE BEEN TEST-FIRED TO ASSURE THEIR
OPERATIONS AND QUALITY!

Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.

If utilizing one of Wolf Steel's trim or surround kits, see "FRAMING" section for removal of the top extension.

NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.

CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.22b-2009 & ANSI Z21.50b-2009, VENTED GAS FIREPLACE/FOYER A GAZ VENTILE.

MADE IN CANADA / FABRIQUE AU CANADA

SERIAL NUMBER/NO. DE SERIE:

BGNV40 / BCNV400

WOLF STEEL LTD, BARRIE, ON, CANADA

MANIFOLD PRESSURE: 3.5" WATER COLUMN

PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU

MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN

PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU

MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN

PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU

NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS AND COVERS CERTIFIED WITH THIS UNIT ONLY.

MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
ET COUVERTURES SEULEMENT AVEC CETTE UNITE.

AVERTISSEMENT:

N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER

EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR
LE FABRICANT.

THE APPLIANCE MUST BE VENTED USING "B" VENT. SEE OWNERS INSTALLATION MANUAL FOR
VENTING SPECIFICS.

L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'EVENT "B". REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE.

ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-KT

W385-0250_C

VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, AND
BED-SITTING ROOM INSTALLATION.

FOYER A GAZ VENTILE. HOMOLOGUE POUR INSTALLATION DANS UNE
CHAMBRE A COUCHER, ET UN STUDIO.

MODEL BGNV40N

MODEL BCNV400N

ALTITUDE / ELEVATION
INPUT / ALIMENTATION

REDUCED INPUT / ALIMENTATION REDUITE

ORIFICE / INJECTEUR

0-4500FT (0-1370m)
30,000 BTU/h
20,000BTU/h
#52

MODEL BGNV40P

MODEL BCNV400P

0-4500FT (0-1370m)

30,000 BTU/h

20,000BTU/h

#39

WARNING:

DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN

CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:

TOP/ DESSUS

0

RECESSED DEPTH / PROFONDEUR D'ENCASTRE

25 ¼"

"

1

T

N

E

V

E

/

T

N

E

V

0

R

E

H

C

N

A

L

P

/

R

O

O

L

F
SIDES / COTES

0

"

5

U

A

E

T

N

A

M

/

E

L

T

N

A

M

*

BACK / ARRIERE

0

*

MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 3".

SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL
D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.

REFERENCE # W/N 15511

INSTALLER: It is
your responsibil-
ity to check off the
appropriate box
on the rating plate
according to the
model, venting and
gas type of the ap-
pliance.

For rating plate loca-
tion, see “INSTALLA-
TION OVERVIEW”
section.

4.1

If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.

If the optional fan or blower is installed, the junction box must be electrically connected and grounded in
accordance with local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/
NFPA 70 National Electrical code in the United States.