beautypg.com

Pg. 16 . . trouble shooting, Trouble shooting – Napoleon Fireplaces OS10-3 User Manual

Page 16

background image

Document n° 1092-1 EN ~ 04/02/2002

16

SYMPTOM

PROBLEM

TEST SOLUTION

Flames extinguish during lighting.

Very cold chimney. No draft established - leave door ajar until fire has caught.

- check air supply in the room

Fire extinguishes once firestarter has

burnt off.

Fuel tank is empty

- fill tank

Fuel valve is closed.

-open valve

Main carburetor float not engaging.

- de-press the safety lever

Control knob is set on “0"

- adjust control knob to ”1"

Fire extinguishes during use.

Fuel tank is empty.

- fill tank

Insufficiant draft

- call your installer

Flame is excessely large, smokey and

sooty.

Fuel adjustment made too quickly.

- return control knob to “1"; wait for

normal combustion. (catalyser should

glow red) Wait 5 to 15 minutes between

each adjustment.

Stove burns noisily, extinguishes and

relights itself.

Burner contains excess fuel

- adjust to lower setting. If problem

persists call your installer.

Insufficient fuel

- check that the de-scaler, the

carburetor filter and burner pot are

cleaned.

Fire smokes.Soot build up noticed.

Flame imbalance

Insufficient air supply.

- increase fresh air supply (open door,

window; add make up air supply)

Downdraft or blockage in chimney

- Check Chimney for Soot build up.

clean if necessary.

- ensure chimney height is sufficient

and cap is not affected by any nearby

obstructions.

- room is in negative pressure. Increase

fresh air supply. Check draft with draft

meter and adjust if not to requirements.

See page .

Oil flow is too low on 1 setting.

- adjust low flow rate while control is set

on “1", call your installer.

Stove is not level. Flame imbalance.

Check level. Adjust if necessary.

Catalyser not centered. Uneven fuel

distribution resulting in secondary air

shortage.

Center catalyser assembly

Insufficient fuel

- check that the de-scaler, the

carburetor filter and burner pot are

cleaned.

The draft regulator is blocked in open

position

- unlock the draft regulator.

- check the regulator adjustment (p. 10)

and refit, if necessary.

Coke build up noticed.

Excessive air supply.

- adjust draft.

TROUBLE SHOOTING

Document

1092-1

EN

~

04/02/2002