beautypg.com

Operation / maintenance – Napoleon Fireplaces GD70NT-S User Manual

Page 21

background image

21

W415-0434 / C / 03.24.05

A. This fireplace is equipped with a pilot which must be

lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for

gas and next to the floor because some gas is heavier
than air and will settle on the floor.

C. Use only your hand to turn the gas control knob. Never

use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under wa-
ter.

GAS KNOB

When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the "burn-in" of
internal paints and lubricants used in the manufacturing
process and will not occur again. Simply open a window to
sufficiently ventilate the room.

After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles in the heat exchanger burning off. Open a window
to sufficiently ventilate the room.

PURGE ALL GAS LINES WITH THE GLASS DOOR OF

THE FIREPLACE OPEN. ASSURE THAT A CONTINU-

OUS GAS FLOW IS AT THE BURNER BEFORE

CLOSING THE DOOR.

• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your building.

• Immediately call your gas supplier from a neighbour's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

WARNING: The gas valve has an interlock device which
will not allow the pilot burner to be lit until the thermo-
couple has cooled. Allow approximately 60 seconds for
the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed
slightly.
1.
Stop! Read the above safety information on this label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise

to off.

4. Wait five (5) minutes to clear out any gas. If you smell

gas including near the floor. Stop! Follow "B" in the
above safety information on this label. If you don't smell
gas go the next step.

5. Turn gas knob counter-clockwise

to pilot.

6. Depress slightly and hold gas knob while lighting the

pilot with the push button ignitor. Keep knob depressed
for one minute, then release. If pilot does not con tinue
to burn, repeat steps 3 through 5.

7. With pilot lit, depress and turn gas knob counter-clock

wise

to on.

8. If equipped with remote on-off switch/thermostat, main

burner may not come on when you turn valve to on.
Remote switch must be in the on position to ignite
burner.

9.Turn on all electric power to the fireplace.

1. Turn off all electric power to the fireplace if service is to

be performed.

2. For a complete shut-down procedure: push in gas con-

trol knob slightly and turn clockwise

to off. Do not

force.

3. For a temporary shut-down procedure: set thermostat

to lowest setting or remote switch to off. Press and turn
the gas knob clockwise

to pilot.

OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

WHAT TO DO IF YOU SMELL GAS

FIGURE 55

FIGURE 56

This manual is related to the following products: