beautypg.com

Fan speed child proof function, Remote auxiliary outlet, Low battery / manual bypass – Napoleon Fireplaces GD82NT-T User Manual

Page 23: Fan control module

background image

23

W415-0666 / 01.28.08

FIGURE 57

FIGURE 58

Flame OFF

Flame at level 1

FIGURE 59

FIGURE 60

Flame at level fi ve

Flame at “HI” level six

FAN SPEED

CHILD PROOF FUNCTION

If the appliance is equipped with a hot air circulating fan, the speed
of the fan can be controlled by the remote system. The fan speed
can be adjusted through six (6) speeds.

1. Use the Mode key to guide you to the fan control icon.

2. Use the Up/Down Arrow keys to turn ON/OFF or adjust the fan
speed.

A single “beep” will confi rm reception of the command.

This function will lock the keys to
avoid unsupervised operation.

1. Press the MODE and UP keys at
the same time.

2. To de-activate this function,
press the MODE and UP keys at
the same time.

FIGURE 61

FIGURE 62

Blower off

Blower “HI” level six

FIGURE 63

REMOTE AUXILIARY OUTLET

The auxiliary function controls the Night Light™.

1. Use the Mode Key to guide you to the AUX icon.

2. Pressing the Up Arrow Key will activate the light.

3. Pressing the Down Arrow Key will turn the light off.

A single “beep” will confi rm the reception of the command.

FIGURE 64

FIGURE 65

LOW BATTERY / MANUAL BYPASS

The life span of the remote batteries depends on various factors: qual-
ity of the batteries, the number of ignitions, the number of changes
to the room thermostat set point, etc.

When the transmitter batteries are low, a Battery Icon will appear on
the LCD display before all battery power is lost. When the batteries
are replaces this Icon will disappear.

When the receiver batteries are low, no “beep” will be emitted from
the receiver when it receives an ON/OFF command. This is an alert for
the receiver that there’s low battery. When the batteries are replaced
the “beep” will be emitted from the receiver when the ON/OFF Key
is pressed.

If the batteries of the receiver or
transmitter are low, the appliance
can be turned on manually by sliding
the three position slider switch on the
receiver to the “ON” position. This
will bypass the remote control fea-
ture and the appliance main burner
will come on if the gas valve is in the
“ON” position.

FIGURE 66

To restore button function temporarily, press the Up and Down
buttons in the following sequence:

up-down-down-up-down

If no button is pressed within 2 minutes, the transmitter will return
to the Child-Proof mode.

Refer to remote operation.

The receiver will emit a “beep” sound to confi rm program-
ming has been successful once power is restored.

IN THE EVENT OF A POWER FAILURE

Fan Control Module (FCM) offers the added ability to control the
fan speed through six (6) speeds, a remotely actuated 120V AUX
outlet and a constantly powered 120V outlet. The FCM provides
DC power to the receiver allowing the batteries to be used only
when line power is interrupted or lost.

Note: Control module ON/OFF switch should always be in the
“ON” position. If for any reason the module is turned OFF the
components plugged into the module won’t have power.

MAINS VOLTAGE PLUG

FAN OUTLET PLUG

AUX OUTLET PLUG

MAINS VOLTAGE

SUPPLY CORD

MODULE ON/ON SWITCH

COMMUNICATION BUS (3 PIN)

FIGURE 67

FAN CONTROL MODULE