Planar LC12 User Manual
Page 20

Title: Product Specification: LC12 High-Bright Monitor
Page 20 of 24
Document Number: 023-0284-01
Revision: A
•
Electromagnetic Immunity
EN 50082 part 1:1992
8.3 RFI Emission Certification
The Monitor is certified to the following emissions standards when installed in customer product
configuration:
•
FCC, Part 15, Paragraph 15.107(b) and 15.109(b), Class A RFI emissions standard.
•
EN 55022 Class A: 1994 ? Limits and measurements of radio interference characteristics of
information technology equipment.
•
IEC 1000 3-?2/1995; EN 61000-?3-?2
Current Harmonic Tests
•
IEC 1000 3-?3/1995; EN 61000-?3-?3
Voltage Fluctuation and Flicker Tests
8.4 System Transient Disturbance Requirements
The Monitor meets the following system transient disturbance requirements:
8.4.1
Electrostatic Discharge
The Monitor performs normally when subjected to static electricity discharges from
persons touching the external surfaces of the Monitor. Performance is verified by
testing according to EN 50082-1 (Ref IEC 801-2:1984) at severity level 3 (4 Kv contact
discharge, 8 Kv air discharge).
8.4.2
Electromagnetic Energy Susceptibility Requirements
The Monitor performs normally in an electromagnetic field with a strength of 10-
volts per meter from 10 KHz to 1 GHz. (REF CISPR 22).
The Monitor with appropriate cables is designed to comply with applicable EMC and
Safety standards as noted in sections 2.31 and 2.3.2.
8.5 Labeling
Where applicable, the Monitor complies with IEC 60417 – Graphical Symbols for Use on
Equipment
8.6 Color Coding
Where applicable, the Monitor complies with ISO 3864 – Safety colors and Safety Signs
9.0 Reliability
9.1 Design Workload
The Monitor is capable of operating 24 hours a day, 365 days a year under the specified
environmental conditions per section 3.1.