beautypg.com

Planar LC12 User Manual

Page 10

background image

Title: Product Specification: LC12 High-Bright Monitor

Page 10 of 24

Document Number: 023-0284-01

Revision: A

where 0-mv is minimum luminance. Rise and fall times for the input signal (10% -

90%) will be ?5-ns (Figure 6).

When terminated with a 75-ohm termination, the dark state (black level) is defined

as a level between 0-mv and 10-mv. The white state (full white) is dependent on the
VGA controller driving the Monitor. Maximum levels may range from 550-mv to 714-

mv. Nominal 680-mv input voltage shall be defined as the default for supplier setup

requirements.

Displayed image intensity and colors will change linearly with the video analog

input. This is necessary to provide a uniform user color change on the screen in

response to a uniformly stepped analog input. The Monitor must be capable of
resolving a minimum color range of 262,144 displayable colors (6 bit resolution for

Red, Green and Blue). This interpolates to 64 shades of gray (or color) at the Red,
Green, and Blue analog video inputs. Accomplishing specified shades of gray

requires a “Video Gain” control adjustment (Section 15.0 ) of Red, Green, and Blue

analog input signals based on the maximum output level range previously specified.

RISE
TIME

FALL

TIME

NEG

POS

HIGH

STEADY

LEVEL

LOW

STEADY

LEVEL

OVERSHOOT

Figure 5. Rise / Fall Time

4.2.2

Synchronization

Sync pulses for horizontal and vertical are TTL levels. Figure 8 defines the levels and

drive current capabilities.