Electrical requirements – Port-A-Cool SERIES 2000 User Manual
Page 8

PORT-A-COOL® Hazardous Location Units
*
Water supply inlet pressure should be limited to 50 psi maximum.
The cooling pads may now be replaced by reversing the removal operation above in Section I. Paragraph B.
Electrical Connection
PORT-A-COOL® unit must be upright and sitting on caddy with cooling pads installed!
These models utilize a single power cord and control switches. The power cord on this unit is 50’ of 14-gauge
3-wire	grounded	cord	with out	plug,	so	the	unit can	be	wired	to	meet	local	code	requirements.	Check	the	chart	below	
to	determine	what	the	electrical	requirements	for	your	specific	model	may	be.	The	use	of	separate	multiple	outlet	
devices	is	not	recommended.
When making electrical connections, insure that local and national codes are adhered to.
ELECTRICAL REQUIREMENTS
PORT-A-COOL®
VOLTS
MAX
MAX
MODEL
+- 10
FREQUENCY
AMPS
WATTS
PAC2K36EP
115
60
13.6
1200
PAC2K48EP
115
60
18.1
1750