Dimensions

>PC< TBMU448

RGB 2 IN

VD

SYNC/HD

B/P

B

G/Y

R

R/P

SERIAL

REMOTE 1

REMOTE 2 IN

IN

OUT

LAN

DVI-D IN

RGB 1 IN

VIDEO IN

S-VIDEO IN

IN

OUT

86.5

167

157

530

436

368

425

441

4

12

R30

478.5

unit : mm

Installation dimensions diagram

• Leave a clearance of at least 50 cm so that the ventilation opening on the rear panel will not be

blocked.

• Be careful not to retain exhausted air on the back side of the main unit. Also take steps to ensure

that the hot air blown out from the air exhaust outlet will not be sucked into the air intake.

• Install with clearances of at least 30 cm provided for the side panels to enable the air filter to be

removed and re-installed.

• When operating the projector in an enclosure, ensure that the temperature of the surrounding air

within the enclosure remains within the range 0 °C to 40 °C while the projector is running. Also
ensure that the air intake and exhaust vents are unobstructed. Even when the surrounding air
temperature is maintained below 40 °C, operation of the protection circuit could cause a shutdown
due to hot exhaust air being trapped inside the projector. When designing the enclosure, please
give due consideration to the thermal environment surrounding the projector (Figure 2).

Attention

;;

;

50 cm or more

Exhaust

30 cm or more

30 cm or more

(Figure 1 : Dimensions applying when one unit is used)

50 cm or more

50 cm or more

Exhaust

10 cm or more

Exhaust

50 cm or more

(Figure 2 : Dimensions applying when two units are used)