Philips 201B4 User Manual
Page 7
![background image](/manuals/188363/7/background.png)
201B Product Information
SCANNING
• Horizontal scanning
30 - 115 KHz
• Vertical scanning
50 - 160 Hz
VIDEO
• Video dot rate
320 MHz
• Input impedance
- Video
75 ohm
- Sync
4.7 kOhm
• Input signal levels
0.7 Vpp
• Sync input signal
Separate sync
Composite sync
• Sync polarities
Positive and negative
WHITE COLOR TEMPERATURE
Chromaticity CIE coordinates:
• at 9300 K degrees
x = 0.283 / y = 0.297
• at 6500 K degrees
x = 0.313 / y = 0.329
• at 5500 K degrees
x = 0.332 / y = 0.347
sRGB
sRGB is a standard for ensuring correct exchange of colors between different devices (e.g. digital cameras, monitors, printers,
scanners, etc.)
Using a standard unified color space, sRGB will help represent pictures taken by an sRGB compatible device correctly on your
sRGB enabled Philips monitors. In that way, the colors are calibrated and you can rely on the correctness of the colors shown
on your screen.
Important with the use of sRGB is that the brightness and contrast of your monitor is fixed to a predefined setting as well as the
color gamut. Therefore it is important to select the sRGB setting in the monitor's OSD.
To do so, open the OSD by pressing the OK button on the front of your monitor. Use the down button to go to Color
temperature and press OK again. Then move the down button to go to sRGB and press OK again.
Exit this OSD.
After this, please don't change the brightness or contrast setting of your monitor. If you change either of these, the monitor will
exit the sRGB mode and go to a color temperature setting of 9300K.
* These information are subject to change without notice.
file:///D|/EDFU/crt_19_5/edoc/english/201B/PRODUCT/PRODUCT.HTM (2 of 5)2005-04-21 ¤W¤И 09:39:07