Pella Replacement Window 80YV0102 User Manual
Page 5
C2
C3
C. Remove Interior Frame Cover #2.
The cover on vent units where the crank handle and roto-cover will be located.
For Standard Awning, single units greater than 42" in height and multiple window
combinations.
1. Starting at the cover end
closest to where the crank
handle will be located, insert
the tool between the sash and
cover (using the same method
of insertion used for Interior
Frame Cover #1).
Note: Insert the tool under
Interior Frame Cover #2 next
to the FRAME CORNER (C2).
2. Pull the tool away from the frame to start releasing the cover barbs from the frame kerfs.
3. When the cover begins to pull away from the frame, relocate the tool near the end of
the cover as shown and continue to pull up to release the barbs from the kerfs.
4. When the cover has been released near the crank handle cut-out, reposition the tool
with the hook under the front edge of the cover. Slide the tool over while pulling up on
the cover. Continue along the length of the cover until it is removed.
C4
C4
NOTE
Cover support bracket
AWNING/
CASEMENT
D. Remove Interior Frame Cover #3.
The cover on vent units on the opposite frame side from where the crank handle is located.
For Standard Awning greater than 42" in width, single units greater than 42" in height and
multiple window combinations.
1. Start at one end of the cover and insert the tool
between the frame and cover as shown.
2. Pull the tool away from the frame to start releasing the
cover barbs from the frame kerfs.
3. When the cover begins to pull away from the frame, grasp
the cover and continue to pull to release the barbs from
the kerfs, removing the cover.
D1
TWO OR MORE PEOPLE ARE REQUIRED FOR THE FOLLOWING STEPS
Note: Take note of the cover
support bracket around the
roto operator hardware, (on
the sill of casement and
large awning units and on
the jamb of standard awning
units) as the cover support
bracket will be referenced
when re-installing Interior
Frame Cover #2.