Boiler dimensions site requirements, Site requirements, Baxi bermuda bbu he – Baxi Potterton BERMUDA BBU HE User Manual

Page 9

background image

560mm mi

n

SURROUND OR FINISHED
WALL FACE

560mm minimu

m

590mm maximum

570mm minimu

m

305mm minimum

Solid, non combustible hearth
to support the boiler,

as specified in BS 5871.

HEARTH
LEVEL

Fireplace
Opening

390mm min

490mm max

584mm min

595mm ma

x

570mm mi

n

Builders

Opening

(575mm max Valour Dimensio

n

Regalia ONLY

)

560mm mi

n

SURROUND OR FINISHED
WALL FACE

560mm minimu

m

590mm maximum

570mm minimu

m

305mm minimum

Solid, non combustible hearth
to support the boiler,

as specified in BS 5871.

HEARTH
LEVEL

Fireplace
Opening

390mm min

490mm max

584mm min

595mm ma

x

570mm mi

n

Builders

Opening

(575mm max Valour Dimensio

n

Regalia ONLY

)

538mm

306mm

383mm

9

Boiler dimensions

Site requirements

Site requirements

1 To accommodate the firefront without the need for additional spacers, there must be a gap of at least 95mm from the surround or finished face to the front

of the boiler.

2 If necessary this gap can be increased by the use of Frame Extension Kits. Each extension increases the effective depth of the opening by up to 50mm.

Alternatively, a range of rebated fire surrounds are available (please see page 13 for details).

Baxi Bermuda BBU HE

CONTROLS
Boiler

Sales Code

710153301

Concealed User Controls

Yes

User Adjustable CH Temperature

Factory Preset

LED Status/Fault Diagnosis Display

Yes

GAS
Gas Supply Pipe Size

mm

15mm compression

Natural Gas

Yes

LPG (Butane/Propane)

No

Nominal Inlet Supply Pressure

m

3

/hr

20

Maximum Gas Rate

1.63

Heat Input Central Heating

kW Max Gross

17.1

kW Max Net

15.38

Heat Output CH Non Condensing

kW Max

15

Heat Output CH Condensing

kW Max

15.7

Seasonal Efficiency

%

90.1

SEDBUK Rating

Band

A

Nox Class

5

Nox Levels

mg/kWh

31

ELECTRICAL
Electrical Supply

Volts/Hz

230/50Hz

Permanent Live Required

Yes

Electrical Cable Required

3 core x 0.75mm

2

Power Consumption

Watts

112

External Fuse Rating

Amps

3

Internal Fuse Rating

Amps

3.15

Ingress Protection Rating

IPXO

Pump Overrun

not required

MECHANICAL & HYDRAULIC
Compartment Ventilation Required

No

Flow & Return Pipe Size

mm

22 male copper

Condensate Discharge Pipe Connection

mm

10

Bypass Required

Yes (pressure operated)

Vertical Pipe Route

no inverted pipework permitted

CH System Inhibitor Required

Yes

CONCENTRIC FLUE SYSTEM
Outside Diameter

mm

100

Max Equivalent Length Vertical

m

10 or 12.5

WEIGHTS
Max Installer Lift Weight

kg

27

Gross Packaged Boiler Weight

kg

28

ACCESSORIES
Right Hand Plumb Kit

Sales Code

720111701

BBU Condensate Pipe Adaptor

Sales Code

720415801