beautypg.com

Preventative maintenance – Pitco Frialator RSCPE14 User Manual

Page 16

background image

PREVENTATIVE MAINTENANCE

12

WARNING

The power supply must be
disconnected before cleaning
and servicing this appliance!

3.2. MONTHLY PREVENTATIVE MAINTENANCE
Water can leave mineral deposits inside the tank. Performing the monthly preventative maintenance
steps below will keep your equipment safe and at peak performance. If you are producing high
quantities of pasta or your water is heavily mineral based, then it may be necessary to clean these
components more then once a month.

3.2.1. DELIMING

1. Read the “operation” section of this manual prior to filling or operating the appliance.

2. Following the manufacturer’s deliming instructions, remove deposits from the tank’s interior.

3. When cleaning is complete, rinse the inside of the tank and its components thoroughly with

cool water. Continue to rinse at least twice or until the cleaner has been completely and
thoroughly rinsed from the tank.

4. Using a clean dry cloth, wipe out all of the water.

5. Repeat the previous steps to clean the rinse tank (if equipped).

3.3. ANNUAL/PERIODIC

PREVENTATIVE MAINTENANCE AND INSPECTION

This section should ONLY be performed by a qualified service technician as part of a regular kitchen
maintenance program. This inspection should take place a minimum of once a year by an Authorized
Service Technician recommended by Pitco. It may be
necessary perform this inspection more then once a year.

3.3.1. HEATING

ELEMENT

9

Check if the element is mechanically strong and in

good condition. Look for scale build up and inspect for
signs of repeated dry firing.

9

Verify element wires are in good working condition. Look for damage to wires or frayed

insulation. Check that the insulation is dry.

9

Verify that bulkhead connections/nut is tight and leak free. Look for water stains and wet

surfaces.

9

Verify amp-draw is within range as compared to the information on the data plate.

3.3.2. TEMPERATURE PROBE & HIGH LIMIT PROBE
9

Verify probes are in good working condition. Check for damage and that the fasteners are

tightly secured to the tank.

9

Verify compression fittings are leak free.

9

Check wiring for loose electrical connections.

3.3.3. CONTROLLER
Perform the following inspection if the appliance is equipped with a temperature controller.
9

Verify that the controller is in good mechanical condition. Check all lights, displays and

switches to assure that they are working properly. Examine overlay for damage that could
allow moisture to enter.

9

Check for loose electrical connections.

9

Verify simmer temperature. Check temperature 1” above controller probe, if necessary check

probe resistance.

9

Check drain valve interlock (if provided) to ensure that the appliance stops heating when the

drain valve is open.