PEAK-System Technik RS-232 User Manual
Page 31

PCAN-USB Hub – User Manual
31
Power Supply
Supply voltage
5 V DC via USB port (bus-powered operation)
9 - 36 V DC via Power socket (self-powered operation)
Power consumption
At 5 V via USB port: max. 300 mA
At 12 V via Power socket: max. 150 mA
(each time without connected USB devices)
Environment
Operating temperature
-40 - 85 °C (-40 - 185 °F)
Temperature for storage
and transport
-40 - 105 °C (-40 - 221 °F)
Relative humidity
15 - 90 %, not condensing
EMC EN
55024:2003-10
EN 55022:2008-05
EC directive 2004/108/EG
Ingress protection
(IEC 60529)
IP20
Measures
Size
105 x 26 x 110 mm (without connection cable)
Cable length
ca. 1.5 m
Weight
300 g (with connection cable)