beautypg.com

How to use external control, About external control, How to use the make/trigger terminal – Panasonic BT-H1700BP User Manual

Page 21

background image

21

HOW TO USE EXTERNAL CONTROL

7

ABOUT EXTERNAL CONTROL

The Multi-Format Monitor has two external control terminals.
One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE (make contact) or TRG. (trigger contact)
method selected in the function setting.

MAKE (make contact system): Controls functions either by short-circuiting (short with GND of 15th terminal) or stable disconnection

(terminal open) of the controlled terminal.

TRG. (trigger system)

: Controls the function by instantaneously (one second) short-circuiting (short with GND of 15th

terminal) the controlled terminal.

* MAKE or TRIGGER are selected from REMOTE SYSTEM in the setup menu.

The other terminal used for remote control is the RS-232C terminal, and this allows the monitor to be controlled by serial
communication.

NOTE: Control priority is in the following order; 1 MAKE/TRIGGER terminal > 2 RS-

232C

terminal > 3 front panel buttons.

When trigger contact is on, the front panel buttons can be operated.

7

HOW TO USE THE MAKE/TRIGGER TERMINAL

No.

Functions to be controlled

Disconnection

Short-circuiting

*1

1

Turns on the tally lamp

Off

On

*2

2

Changes the input to INPUT A

Invalid

Valid

3

Changes the input to INPUT B

Invalid

Valid

4

Changes the input to INPUT C

Invalid

Valid

5

Changes the input to INPUT D

Invalid

Valid

6

Changes the input to INPUT E

Invalid

Valid

7

Changes the input to INPUT F

Invalid

Valid

8

COLOR OFF

Off

On

9

AREA MARKER

Off

On

10

ASPECT

Off

On

11

TALLY SELECT

GREEN

RED

12

AREA MARKER set-up

without “R-”

with “R-”

*3

13

STATUS DISPLAY

ON

OFF

14

External Control

Invalid

Valid

*2

15

GND

*1 : The TRIGGER (trigger contact) system switches each setting by instantaneously (approx. 1 second) short-circuiting (short with GND of 15th terminal) the

controlled terminal.

*2 : TALLY (1st terminal) and EXTERNAL CONTROL (14th terminal) must be controlled with the MAKE (make contact) system even under the TRIGGER (trigger

contact) system.

*3 : Activating each with “R-” or without “R-” setting in the AREA MARKER menu is possible. Refer to “AREA MARKER” on page 14 for details.

Operation

1. Short-circuit EXTERNAL CONTROL (14th terminal) to GND (15th terminal) to activate the external control.
2. Under the MAKE system, controls each function by short-circuiting (short with GND of 15th terminal) or stable disconnection

(terminal open) of the controlled terminal.

3. Under the TRIGGER (trigger contact) system, controls each function by Pulse Control, that is by instantaneously (approx. 1

second) short-circuiting (short with GND of 15th terminal) the controlled terminal.

NOTES:

• When using INPUT A (the 2nd pin) through INPUT F (7th terminal), only the terminal in use should be short-circuited, the others must be

disconnected.

• Under the TRIGGER system, multiple terminals cannot be short-circuited to GND (15th terminal). Be sure to short-circuit the single terminal to

GND.

10

9

8

5 4 3 2 1

7

6

14

15

13 12 11

LCT1464-001A_EN_16-21-B

03.9.19, 14:46

21