5.2 POWER-UP

There is no power switch on the Model 1012ARC: Power is

automatically applied to the Model 1012ARC when its card-edge
connector makes contact with the chassis’ mid-plane socket, or when
the chassis’ power supply is turned on.

The Model 1012ARC is a “hot

swappable” card—it will not be damaged by plugging it in or removing
it while the rack’s power supply is switched on.

When the local and remote Model 1012ARCs are

both

powered up and

are passing data

normally

, the following LED conditions will exist:

• PWR = solid green
• TD & RD = flashing
• CD = solid green

13

APPENDIX A

SPECIFICATIONS

Transmission Format: Asynchronous, half or full duplex

Transmission Line: Two unconditioned twisted pair 19 - 26 AWG

Transmit Level: -6 dBm

Operation: Point-to-point or multipoint

Interfaces: EIA RS-232, CCITT V.24

Data Rates: To 38.4 Kbps

Isolation: Minimum 1500 V RMS transformer coupled

Surge Protection: Silicon Avalanche Diodes

RTS/CTS Delay: 40mS

Connectors: RJ-45 on RS-232 side; RJ-11 or RJ-45 on line side

Power Supply: Rack-mount power supply is switchable between

120V and 240V AC; rack chassis supplies 10V AC to the Model
1012ARC, typical consumption is 700 mW

Internal Interface: Connection to the Model 1000R16 rack chassis

via 50 pin male card edge

Fuse: 400mA for 120V applications; 200mA for 240V applications

Temperature Range: 0-50°C (32-122°F)

Altitude: 0-15,000 feet

Humidity: Up to 95% non-condensing

Dimensions: 0.95”w x 3.1”h x 5.4”l