Signal connections – Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 User Manual
Page 24

18 HFG2.0
USER
GUIDE
Signal Connections
Signals are sent between the HFG2.0 and the user’s controller through
the integral 17-wire signal harness. See Table 1-4 for the wire list for this
harness. See Figure 1-12 for the system signal wiring diagram.
WIRE COLOR
FUNCTION
AWG
WHITE/ORANGE/YELLOW Serial/RX
In
20
WHITE/ORANGE/BLUE Serial/TX
Out
20
WHITE/ORANGE/GREEN Serial
RETURN
20
BLACK OVER
TEMP
Alarm
20
WHITE/BLACK
OVER TEMP Alarm RETURN
20
ORANGE FAULT
Alarm 20
WHITE/ORANGE
FAULT Alarm RETURN
20
VIOLET RUN
Command
20
WHITE/VIOLET
RUN Command RETURN
20
GRAY RESET
Command
20
WHITE/GRAY
RESET Command RETURN
20
BROWN Position
Demand
20
WHITE/BROWN
Position Demand RETURN
20
YELLOW Position
Feedback
20
WHITE/YELLOW
Position Feedback RETURN
20
BLUE Motor
Current
20
WHITE/BLUE
Motor Current RETURN
20
Table 1-4. Wire List for HFG2.0 System Signal Harness